Revision history of the Tani OPC client toolkits for OPC UA, OpcPipe and OPC DA
The newest information is on top.
Version 2021.7.29
- The c# version circumvalates an effect in the c# garbage collector. In writing data into the PLC the confirm pointer is separately pinned.
Version 2020.9.28
- Adapted to OPC server version 2.
Version 2020.7.13
- Service release with some optimizations.
Version 2019.7.9
- OPC UA now handles variables with the type LocalizedText and QualifiedName.
Version 2019.5.14
- An OPC UA connection establish effect is fixed: uncommon time values are adjusted.
Version 2019.5.2
- An OPC UA effect is fixed: uncorrect time values are adjusted. This will prevent session errors.
- A call to OpcUaSetGlobalSettings from an older client does not reset the time values.
Version 2018.8.10
- The OPC client libraries are now much faster in the creation of many elements.
- All toolkits now are containing the c# access example.
- For c# the API is changed so no "unsave" keywords are needed anymore above this interface.
Strings are handled native also.
The program example now is containing a structure usage example.
The c# toolkit nedds the OpcPipe library from version 4.03.
Version 17.7.2018
- Stability issues on heavily loaded systems with lot of connections and often broken connections are fixed.
Version 13.5.2018
- Structures are supported now.
- Bugs fixed
- A bug in conjunction with the SSL libraries from multiple Linux distribution is fixed.
Version 26.4.2018
- Now a OPC DA toolkit exists.
- The OPC UA and OpcPipe toolkit now supports structures. OPC DA does not know from this.
- The sources are separated in multiple files.
- Bugs fixed
- The OPC UA libraries are adapted to the 2018 versions of SSL. Some stability issues in conjunction with certificates are fixed.
Version 25.10.2017
- Bugs fixed
- In dynamically created connections the setting "Write allowed" now works.
Version 17.10.2017
- Bugs fixed
- Dynamically created floors are on the correct floor now always.
- Browse one item uses the internal cache. Forcing a cache update will be done with browse items.
Version 11.10.2017
- Bugs fixed
- The OPC UA browsing for the search of later findable elements handles the tomeout for all elements properly.
Version 2.10.2017
- Variablen which will be used over OPC UA client cyclic will be rebrowsed all 30s if they can not be found.
- More OPC UA server errors from some machines are bypassed: Wrong reply to Publish rquests.
Version 12.7.2017
- Bugs fixed
- OPC UA client connections do not break after hundred thousands of write operations.
Version 30.6.2017
- Bugs fixed
- The creation of single string variables over the OPC UA service CreateNode works stable again. This was damaged during the sting array extension.
Version 8.6.2017
- String Arrays are supported now.
Version 18.4.2017
- The timeout in OPC UA and OpcPipe client connections now possible.
- All libraries which are containing security functions are actualized.
- Bugs fixed
- A stability issue in OPC UA is fixed. Now the connection establishing on devices with very slowly encryption functions works stable.
Version 30.1.2017
- OPC UA now supports file read and write.
- Bugs fixed
- Extremly long comments - more than 20K of data - do not affect the OPC interfaces.
- The OPC UA client now works with 256 bit certificates.
Version 28.11.2016
- New: OPC UA now supports security. All possible security functions can be used. With the configuration software the easily the certificates can be managed.
Version 18.10.2016
- Bugs fixed
- OPC UA server connections do not hang if multiple elements will be disconnected in one request.
Version 28.07.2016
- Bugs fixed
- Stability error in OPC UA fixed. The error did occure on big amounts of data and relatively slowly network connections.
Version 2.02.2016
- Linux Raspberry Pi version installer now starts the OPC server
directly without reboot.
Version 25.11.2015
- Optimization in OPC UA Client during browse.
Version 20.11.2015
- OPC UA now tested successfully in OPC Foundation interoperability
event in Nuremberg.
Tani GmbH, Freiligrathstraße 12, 90482
Nürnberg phone: 0911/98037354 E-Mail: info@tanindustrie.de HRB:
Amtsgericht Nürnberg 29562