OPC-Server for common PLCs

Tani OPC Server

OPC-Server connects computers with visualization or SCADA software with controllers of various manufacturers. The Tani-OPC-Server Ethernet allows accessing to controller from Siemens, Rockwell Automation, Wago, Modicon, Schneider Electric and others. The communication is very fast, easily to configure and allows lot of diagnostics and overviews.

At a glance

The Tani OPC Server supports the functions You will need. The Ethernet protocol You are using depends from the controllers and devices in Your plant. So this one service communicates with all the controllers.

Features

Application area

All-in-One-OPC-Server with maximum protocol and controller scope for various controller types and OPC variants and operation systems

OPC servers are made for heterogeneous networks with different controllers and devices from lot of different vendors. With the extensive diagnostics for easily commissioning it replaces lot of other OPC servers.

Supported
operation systems
  • Windows 7, 8, 8.1, 10. Older versions as XP and Vista also. 64 and 32 bit.
  • Windows Server 2008, 2012, 2016 and 2018
  • Linux on the Raspberry and Odroid computers
  • Linux on the Wiesemann & Theis pure.box 3
  • Linux on a PC with Debian, Ubuntu, Suse, Redhat and other Distributions
  • Linux 64 Bit as Docker or Kubernetes Container
Supported
OPC interfaces
  • OPC Pipe Open interface
  • OPC UA (Unified Architecture)
  • OPC DA (Classic OPC over DCOM, available under Windows only)
Supported
controller types
and devices
  • Siemens S7 sobre RFC1006 e Sinec H1. Há suporte para os S7 200, 300 e 400, 1200, 1500. No ald S7 1500, a família de 1200, os blocos de dados otimizadas são suportados, todos os símbolos e comentários são navegadas online. Siemens CP ou a interface Ethernet a bordo do CPU pode ser usado. Mainstream MPI Gateways como Hilscher Netlink, Helmholz Netlink, IBH Softec Netlink, INAT Echolink, Processo Informatik S7Lan ou Softing Netlink são suportados também. sistemas compatíveis S7 como VIPA Speed7 pode ser usado, também
  • Siemens S5 over RFC1006, PLC Header, RAW or Sinec H1. Supported are Siemens CPs, INAT CPs, Helmholz CPs, IBH Softec S5Net, Process Informatik S5Lan.
  • Rockwell Compact Logix y Control Logix, firmware antes e depois versão 21.
  • varios Modbus/TCP devices
    • Modicon
    • Schneider
    • Wago
    • Beckhoff
    • Phoenix Contact
  • Raw data.
Comunica através de Ethernet

From Tani OPC-Server supported PLC protocols



BasisSiemensRockwellMitsubishiBACnetDe LuxeDe Luxe H1
Transport-
protocols
TCP/IP
OSI/H1





Application-
protocols
Siemens S7
Siemens S5




ControlLogix
CompactLogix




Mitsubishi



BACnet



Modbus
Send / Receive
DCOM Tunnel

Order Numbers

Opc Server Standard Siemens, 50 connections 10000 items101-0011-01
Opc Server Standard Rockwell, 50 connections, 10000 items101-0021-01
Opc Server Standard Mitsubishi, 50 connections 10000 items101-0051-01
Opc Server De Luxe H1, 100 connections, 100000 items101-0041-01
Opc Server Standard Basis, 50 connections, 10000 items101-0001-01
Opc Server De Luxe, 50 connections, 10000 Items101-0031-01
Opc Server Tunnel101-0000-01
Opc Server Minimum Siemens, 1 connection, 1000 items101-0111-01
Opc Server Minimum Rockwell, 1 connection, 1000 items101-0121-01
Opc Server Small Siemens, 5 connections, 3000 items101-0311-01
Opc Server Small Rockwell, 5 connections, 3000 items101-0321-01
Expands Standard OPC Server or Standard PLC Engine with controller Redundancy100-0001-01
Expands Standard OPC Server or Standard PLC Engine to 1000 connections100-0001-02
Expands Standard OPC Server or Standard PLC Engine to 100 000 (hundred thousand) items101-0001-06
Expands Standard OPC Server or Standard PLC Engine to 200 connections and 1 000 000 (one million) items101-0001-02
Expands standard OPC Server or standard PLC Engine with OPC DA client100-0001-03
Expands Standard OPC Server or Standard PLC Engine to BACnet IP Access100-0001-04
Expands Standard OPC Server or Standard PLC Engine to create variables dynamic101-0001-04
Expands Standard OPC Server or Standard PLC Engine to read PLC program code101-0001-03
Upgrade OPC Server to PLC Engine101-0001-07

Software protection with dongle

OPC Server download

Without a license all OPC Servers will work for three days after each start.