OPC Server
OPC-Server connects computers with visualization or SCADA software with controllers of various manufacturers. The Tani-OPC-Server Ethernet allows accessing to controller from Siemens, Rockwell Automation, Mitsubishi, Wago, Modicon, Schneider Electric and others. The communication is very fast, easily to configure and allows lot of diagnostics and overviews.
- Siemens S7 1500 und 1200 with online browse.
- Siemens S7 300/400 with symbol import.
- Siemens S5. All models, all CP.
- Rockwell Control Logix and Compact Logix.
- Rockwell 800 Family.
- Rockwell SLC and PLC5.
- Rockwell extended paths - reach all your PLC over one.
- BACnet and KNX support for building automation. Including structures, trend, calendar, rpc, lists and more.
- Mitsubishi Melsec Q family support.
- IEC 60870-5-104 for the telecontrol.
- All Modbus basing PLC and devices. Modbus TCP and RTU.
- MQTT with a simple symbol handling.
- OPC UA station search (Multicast Discovery).
- Structures as elements. Important for MES and OEE usage.
- Alarms and events.
- OPC UA device search with multicast discovery.
- The communication to the controller is highly optimized, if it gets faster then structures are read instead of many single variables.
- Option network redundancy.
- All OPC variants: OPC UA, Classic OPC (sometimes called OPC DA) and OpcPipe.
- Option historian functions.
- Fast. It is the fastet OPC server on the market always.
- For Windows, Linux, Docker, Raspberry PI, Phytec, Wiesemann &Theis and more.
- Easy configuration, many wizards, no reboots during configuration changes
- Reduction of downtime through integrated diagnostics.
The Tani OPC Server supports the functions You will need. The Ethernet protocol You are using depends from the controllers and devices in Your plant. So this one service communicates with all the controllers.
- No limit to the number of controllers and variables. Depending on the license limitations may exist.
- High degree of reliability for all OPC clients using OPC UA and DA.
- Redundancy for secure communication to the controllers S7 1500 and 1200: Online browse and "optimized data blocks".
- S7 200/300/400: Easy to use Step 7 symbols directly from the Step 7 project.
- All configurations take effect immediately without annoying reboots or restarts.
- Handles data from other OPC devices and servers comfortable with integrated OPC UA Client
- Increased availability with extensive diagnostics.
- Contains a logger for diagnostics, for long time diagnostics also.
- The Windows and Linux versions (Raspberry also) are same in all functions, DCOM alone can be used under Windows.
- 72 hour version with unlimited functionality available here.
- Standard version for 50 controllers and 10000 items.
"All in one" OPC Server with maximum protocol and controller scope for various controller types and OPC variants and operation systems
The Tani OPC servers are made for heterogeneous networks with different controllers and devices from lot of different vendors. With the extensive diagnostics for easily commissioning it replaces lot of other OPC servers.
Tani offers OPC Server for the Raspberry PI, Odroid, PC Linux, Windows, and more.
Classic OPC is also available for Windows.
Expand your market share making your device capable for OPC UA.
Supported operation systems |
|
Supported OPC interfaces |
|
Supported controller types and devices |
|
Basis | Siemens | Rockwell | Mitsubishi | IEC60870 | BACnet | De Luxe | Multix | Maximum | ||
Transport- protocols | TCP/IP | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
OSI/H1 | ✔ | |||||||||
Application- protocols | Siemens S7 1500/1200 300/400 | ✔ | ✔ | ✔ | ✔ | |||||
Siemens S5 | ✔ | ✔ | ✔ | |||||||
ControlLogix CompactLogix SLC PLC5 Micro8xx | ✔ | ✔ | ✔ | ✔ | ||||||
Mitsubishi | ✔ | ✔ | ✔ | ✔ | ||||||
BACnet | ✔ | ✔ | ✔ | ✔ | ||||||
KNX | ✔ | ✔ | ✔ | ✔ | ||||||
IEC 60870-5 | ✔ | ✔ | ✔ | ✔ | ||||||
Modbus | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | |
MQTT | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | |
OPC UA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | |
Send / Receive | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | |
Windows OPC DA classic | ✔ | ✔ |
OPC Server Multix, 100 Client Connections, 50 000 Items | |
Large, 200 Client Connections, 1 000 000 Items OPC Server Multix Large for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 200 PLC Client Connections • 1 000 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 200 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections • 100 IEC104 Client Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • BacNet Connections • KNX Connections • IEC60870-5-104 / DNP3 Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Redundancy Connections • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0031-04 V2 |
IEC60870-5-104 OPC Server Multix + IEC60870-5-104 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 PLC Client Connections • 50 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 200 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections • 100 IEC104 Client Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • BacNet Connections • KNX Connections • IEC60870-5-104 / DNP3 Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0061-02 V2 |
Multix Normal OPC Server Multix for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 PLC Client Connections • 50 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 200 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • BacNet Connections • KNX Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0031-03 V2 |
OPC Server De Luxe, 100 Client Connections, 50 000 Items | |
Osi/H1 OPC Server De Luxe + Osi/H1 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 PLC Client Connections • 50 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 200 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections Licensed features: • TCP/IP Connections • OSI/H1 Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • BacNet Connections • KNX Connections • OpcPipe Server Connections • OPC UA Server Connections • OPC DA Server Functionality • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0041-01 V2 |
Large, 200 Client Connections, 1 000 000 Items OPC Server De Luxe Large for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 200 PLC Client Connections • 1 000 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 200 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections • 100 IEC104 Client Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • BacNet Connections • KNX Connections • IEC60870-5-104 / DNP3 Connections • OpcPipe Server Connections • OPC UA Server Connections • OPC DA Server Functionality • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Redundancy Connections • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0031-02 V2 |
IEC60870-5-104 OPC Server De Luxe + IEC60870-5-104 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 PLC Client Connections • 50 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 200 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections • 100 IEC104 Client Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • BacNet Connections • KNX Connections • IEC60870-5-104 / DNP3 Connections • OpcPipe Server Connections • OPC UA Server Connections • OPC DA Server Functionality • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0061-01 V2 |
De Luxe Normal OPC Server De Luxe for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 PLC Client Connections • 50 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 200 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • BacNet Connections • KNX Connections • OpcPipe Server Connections • OPC UA Server Connections • OPC DA Server Functionality • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0031-01 V2 |
OPC Server XP OPC Server XP for Windows XP • 100 PLC Client Connections • 50 000 Items • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC DA Client Connections • 200 OPC UA Server Connections • 200 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections • 100 IEC104 Client Connections Licensed features: • TCP/IP Connections • OSI/H1 Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • BacNet Connections • KNX Connections • IEC60870-5-104 / DNP3 Connections • OpcPipe Server Connections • OPC UA Server Connections • OPC DA Server Functionality • OpcPipe Client Connections • OPC UA Client Connections • OPC DA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0041-02 V2 |
OPC Server Standard, 50 Client Connections, 10 000 Items | |
Siemens S7 OPC Server Standard Siemens S7 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 10 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 50 OPC UA Client Connections • 50 OPC Pipe Client Connections • 100 OPC UA Server Connections • 100 OPC Pipe Server Connections • 50 MQTT Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Modbus TCP/RTU Connections • Raw Data Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0011-01 V2 |
Siemens S7 DA OPC Server Standard Siemens S7 DA for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 10 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 50 OPC UA Client Connections • 50 OPC Pipe Client Connections • 100 OPC UA Server Connections • 100 OPC Pipe Server Connections • 50 MQTT Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Modbus TCP/RTU Connections • Raw Data Connections • OpcPipe Server Connections • OPC UA Server Connections • OPC DA Server Functionality • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0011-04 V2 |
Rockwell OPC Server Standard Rockwell for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 10 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 50 OPC UA Client Connections • 50 OPC Pipe Client Connections • 100 OPC UA Server Connections • 100 OPC Pipe Server Connections • 50 MQTT Connections Licensed features: • TCP/IP Connections • Serial Connections • Rockwell CompactLogic/ControlLogix Connections • Modbus TCP/RTU Connections • Raw Data Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0021-01 V2 |
Mitsubishi OPC Server Standard Mitsubishi for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 10 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 50 OPC UA Client Connections • 50 OPC Pipe Client Connections • 100 OPC UA Server Connections • 100 OPC Pipe Server Connections • 50 MQTT Connections Licensed features: • TCP/IP Connections • Serial Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0051-01 V2 |
Basis OPC Server Standard Basis for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 10 000 Items • 100 Logic Tables • 1 000 Elements per Logic Table • 50 OPC UA Client Connections • 50 OPC Pipe Client Connections • 100 OPC UA Server Connections • 100 OPC Pipe Server Connections • 50 MQTT Connections Licensed features: • TCP/IP Connections • Serial Connections • Modbus TCP/RTU Connections • Raw Data Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Minimal Logic Tables Functionality • Allows the use of Addon licenses • Dynamic Connection and Variable Creation • Item Redirect Connection | 101-0001-01 V2 |
OPC Server Small, 5 Client Connections, 3 000 Items | |
Multix OPC Server Small Multix for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 5 PLC Client Connections • 3 000 Items • 5 OPC UA Client Connections • 5 OPC Pipe Client Connections • 20 OPC UA Server Connections • 20 OPC Pipe Server Connections • 5 MQTT Connections • 5 KNX Client Connections • 5 IEC104 Client Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • BacNet Connections • KNX Connections • IEC60870-5-104 / DNP3 Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0331-02 V2 |
Siemens S7 OPC Server Small Siemens S7 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 5 PLC Client Connections • 3 000 Items • 5 OPC UA Client Connections • 5 OPC Pipe Client Connections • 20 OPC UA Server Connections • 20 OPC Pipe Server Connections • 5 MQTT Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Modbus TCP/RTU Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0311-01 V2 |
Rockwell OPC Server Small Rockwell for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 5 PLC Client Connections • 3 000 Items • 5 OPC UA Client Connections • 5 OPC Pipe Client Connections • 20 OPC UA Server Connections • 20 OPC Pipe Server Connections • 5 MQTT Connections Licensed features: • TCP/IP Connections • Serial Connections • Rockwell CompactLogic/ControlLogix Connections • Modbus TCP/RTU Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0321-01 V2 |
OPC Server Minimum, 2 Client Connections, 1 000 Items | |
Multix OPC Server Minimum Multix for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Items • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections • 2 KNX Client Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S5 Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Rockwell CompactLogic/ControlLogix Connections • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • BacNet Connections • KNX Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0131-03 V2 |
Siemens S7 OPC Server Minimum Siemens S7 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Items • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections Licensed features: • TCP/IP Connections • Serial Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Modbus TCP/RTU Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0111-01 V2 |
Rockwell OPC Server Minimum Rockwell for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Items • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections Licensed features: • TCP/IP Connections • Serial Connections • Rockwell CompactLogic/ControlLogix Connections • Modbus TCP/RTU Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0121-01 V2 |
OPC Server Nano, 1 Client Connection, 10 Items | |
Siemens S7 OPC Server Nano Siemens S7 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 1 PLC Client Connection • 10 Items • 1 OPC UA Client Connection • 1 OPC Pipe Client Connection • 5 OPC UA Server Connections • 5 OPC Pipe Server Connections • 1 MQTT Connection Licensed features: • TCP/IP Connections • Serial Connections • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Modbus TCP/RTU Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0511-01 V2 |
Rockwell OPC Server Nano Rockwell for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 1 PLC Client Connection • 10 Items • 1 OPC UA Client Connection • 1 OPC Pipe Client Connection • 5 OPC UA Server Connections • 5 OPC Pipe Server Connections • 1 MQTT Connection Licensed features: • TCP/IP Connections • Serial Connections • Rockwell CompactLogic/ControlLogix Connections • Modbus TCP/RTU Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0521-01 V2 |
Building, 50 Items OPC Server Nano Building for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 1 PLC Client Connection • 50 Items • 1 OPC UA Client Connection • 1 OPC Pipe Client Connection • 5 OPC UA Server Connections • 5 OPC Pipe Server Connections • 1 MQTT Connection • 1 KNX Client Connection Licensed features: • TCP/IP Connections • Serial Connections • Modbus TCP/RTU Connections • BacNet Connections • KNX Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0541-01 V2 |
Basis, 1 000 Items OPC Server Nano Basis for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 1 PLC Client Connection • 1 000 Items • 1 OPC UA Client Connection • 1 OPC Pipe Client Connection • 5 OPC UA Server Connections • 5 OPC Pipe Server Connections • 1 MQTT Connection Licensed features: • TCP/IP Connections • Serial Connections • Modbus TCP/RTU Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connections • PLC Data Server Functionality • PLC Access Functionality • Dynamic Connection and Variable Creation • Item Redirect Connection • Doesn't allow the use of Addon licenses | 101-0501-01 V2 |
Addon | |
Redundancy Addon Redundancy for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others Licensed features: • Redundancy Connections | 100-0001-01 V2 |
1 000 Connections Addon 1 000 Connections for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 1 000 PLC Client Connections • 1 000 OPC UA Client Connections • 1 000 OPC UA Server Connections • 1 000 IEC104 Client Connections | 100-0001-02 V2 |
100 000 Items Addon 100 000 Items for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 000 Items | 101-0001-06 V2 |
200 Connections 1 000 000 Items Addon 200 Connections 1 000 000 Items for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 200 PLC Client Connections • 1 000 000 Items • 200 OPC UA Client Connections • 200 OPC UA Server Connections • 200 MQTT Connections • 200 IEC104 Client Connections | 101-0001-02 V2 |
2 500 Connections 4 000 000 Items Addon 2 500 Connections 4 000 000 Items for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 500 PLC Client Connections • 4 000 000 Items • 2 500 OPC UA Client Connections • 2 500 OPC UA Server Connections • 2 500 MQTT Connections • 2 500 IEC104 Client Connections | 101-0001-08 V2 |
OPC DA Client and Server Addon OPC DA Client and Server for Windows 7 and newer on PC • 200 OPC DA Client Connections Licensed features: • OPC DA Server Functionality • OPC DA Client Connections | 100-0001-03 V2 |
BACnet KNX Addon BACnet KNX for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 50 KNX Client Connections Licensed features: • Modbus TCP/RTU Connections • Raw Data Connections • BacNet Connections • KNX Connections • PLC Access Functionality | 100-0001-04 V2 |
Serial Connections Addon Serial Connections for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others Licensed features: • Serial Connections | 100-0001-05 V2 |
PLC Engine Collect Functions Addon PLC Engine Collect Functions for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others Licensed features: • Full Logic Tables Functionality | 101-0001-07 V2 |
DA Server Functions Addon DA Server Functions for Windows 7 and newer on PC Licensed features: • OPC DA Server Functionality | 101-0000-01 V2 |
Siemens S7 Addon Siemens S7 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections Licensed features: • Siemens S7-200/300/400 Connections • Siemens S7-1200/1500 Connections • Modbus TCP/RTU Connections • Raw Data Connections • PLC Access Functionality | 101-0011-02 V2 |
Siemens S5 Addon Siemens S5 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections Licensed features: • Siemens S5 Connections • Modbus TCP/RTU Connections • Raw Data Connections • PLC Access Functionality | 101-0011-03 V2 |
Rockwell Addon Rockwell for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections Licensed features: • Rockwell CompactLogic/ControlLogix Connections • Modbus TCP/RTU Connections • Raw Data Connections • PLC Access Functionality | 101-0021-02 V2 |
Mitsubishi Addon Mitsubishi for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections Licensed features: • Mitsubishi Melsec Q Connections • Modbus TCP/RTU Connections • Raw Data Connections • PLC Access Functionality | 101-0051-02 V2 |
IEC60870-5-104 Addon IEC60870-5-104 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 100 IEC104 Client Connections Licensed features: • Modbus TCP/RTU Connections • Raw Data Connections • IEC60870-5-104 / DNP3 Connections • PLC Access Functionality | 100-0001-06 V2 |
Software protection with dongle
Without a license all OPC Servers will work for three days after each start.